PL0

ETA-certified

Not only complies with European directives, but exceeds them with demonstrable safety, quality and structural performance in demanding applications.

Lifespan

A temporary ground anchor for applications up to two years, the perfect strand anchor for projects where the anchor must be removed upon completion.

Corrosion protection

The corrosion protection is precisely matched to the maximum service life of two years, meaning there are no superfluous costs for this stud bolt anchor.

Information about strand anchor PL0

The Deepro PL0 strand anchor is the cost-effective choice for short-term temporary anchorages. You benefit from an ETA-certified system with full system control, even for the shortest application duration.
Corrosion protection precisely tailored to the temporary usage period of up to two years. A cost-effective solution without unnecessary protective layers or additional costs.
Complete system where all components have been assessed as a cooperative whole under ETA-21/1053. Full system control for any temporary application.
Delivery on reels with an inner diameter of 1.6 to 2.5 metres ensures efficient transport. Ready for processing on-site without pre-treatment.
In-house production means short delivery times and direct quality control. Furthermore, it can be fully recycled after use if the project requires it.

Documentation

PDF

EAD

Download
PDF

Estimated time of arrival

Download

Certification

PDF

CAD files

Download
PDF

3D parts

Download
PDF

3D CAD

Download
PDF

3D model

Download
LifespanUp to 2 years
Beam diameter15.3 mm (140 mm²) of 15.7 mm (150 mm²)
EAD classPLL – Limited corrosion protection
Max. anchor capacityTotal: 6.138 kN (22 strands, 150 mm², fpk = 1.860 MPa)
Number of strands2 to 22 (larger sizes on request)
CertificationETA-21/1053, OIB Vienna – AVCP System 1+

In comparison

PL0

Temporary strand anchor

Lifespan

Up to 2 years

Beam diameter

15.3 mm (140 mm²) of 15.7 mm (150 mm²)

EAD class

PLL – Limited corrosion protection

Max. anchor capacity

To 6.138 kN (22 strands, 150 mm², fpk = 1.860 MPa)

Number of strands

2 to 22 (larger sizes on request)

Certification

ETA-21/1053, Central Office of Public Works Vienna – AVCP System 1+

PL1+

Semi-permanent strand anchor

Lifespan

Up to 7 years

Beam diameter

15.3 mm (140 mm²) of 15.7 mm (150 mm²)

EAD class

PLL - Limited corrosion protection (continuous first layer)

Max. anchor capacity

To 6.138 kN (22 strands, 150 mm², fpk = 1.860 MPa)

Number of strands

2 to 22 (larger sizes on request)

Certification

ETA-21/1053, Central Office of Public Works Vienna – AVCP System 1+

PL2

Permanent strand anchor

Lifespan

Up to 100 years

Beam diameter

15.3 mm (140 mm²) of 15.7 mm (150 mm²)

EAD class

PLE2 – Enhanced corrosion protection (2 interlinked layers)

Max. anchor capacity

To 6.138 kN (22 strands, 150 mm², fpk = 1.860 MPa)

Number of strands

2 to 22 (up to 91 strands on request)

Certification

ETA-21/1053, Central Office of Public Works Vienna – AVCP System 1+

PL3

Permanent strand anchor

Lifespan

100+ years

Beam diameter

15.3 mm (140 mm²) of 15.7 mm (150 mm²)

EAD class

PLC – Comprehensive Corrosion Protection with Electrical Insulation

Max. anchor capacity

To 6.138 kN (22 strands, 150 mm², fpk = 1.860 MPa)

Number of strands

2 to 22 (larger sizes on request)

Certification

ETA requested (Deepro) – EAD basis: EAD 160071-00-0102 – expected issue Q2 2026

Robert Jansen

Technical Sales Manager

Why choose Deepro

Certified quality

Meets the strictest European standards and ETA certification. Tested and proven performance for safe application in critical constructions.

Maximum lifespan

Anchors with a design life of up to 100 years. Reliable performance, even under long-term load and exposure to groundwater.

Advanced Protection

Multi-layered corrosion protection with HDPE casing and sealing systems. Effectively protects against moisture, chemical influences, and external loads.

Technical expertise

Support at every stage of the project, from design to implementation. Practical knowledge and experience ensure an efficient and reliable solution.

Arrange a no-obligation consultation

Every situation is different. In a consultation, we will clearly outline your project and possibilities. You will immediately know where you stand.

Robert Jansen

Technical Sales Manager

Ask your question

What would you like to receive more information about?

Ask your question and we will respond within two working days.

Max. file size: 256 MB.
Privacy Policy(Required)

Frequently asked questions about strand anchors PL0

For projects where removal is planned in advance, the PL0 anchor can be implemented with a removable version of the strands in the bond length.

Following relaxation, the strands can be pulled out via the anchor head. The grout body remains in the ground.

For temporary anchors, the ETA and the applicable standard (NEN-EN 1537 / EN 1997-1) prescribe an initial test, plus periodic checks depending on project duration and risk class.

In practice, monitor anchors are used in PL0 applications, which are read throughout the entire operational phase. We support you in setting up a suitable monitoring plan.

The design life of 2 years is based on the corrosion protection class PLL of the ETA certificate and is binding for the application. If the implementation period is likely to be extended, please contact our technical specialists in advance.

In many cases, it is wiser to opt for a PL1 or PL2 anchor during the design phase, so that you avoid the risk of redesign or replacement.

The required bore diameter depends on the number of strands, the soil structure, and the bonding length design. For most PL0 applications, drilling is carried out using flushing or with a temporary casing, depending on the soil conditions.

Our technical support provides a drilling proposal per project with a recommended diameter, so that the anchor and grout build-up connect correctly.

Download the file

To receive the file, you need to leave an email address.